Cummins Isl 9 2272 Code Case Study

Michael Diagnostician Illinois Posted   Latest   Edited  

Hi everyone here is a case study I just put together. Hope this helps.

+3
Denis Service Manager
Alberta
Denis
   

I have never thought of using the load pro to load a ref circuit. I’ll keep that in mind for next time. As for the load testing with a bulb, Robert Dottered did some tests with a scope to measure inrush current of light bulbs. Definitely worth a look. Good work Michael. youtu​.​be/4Z-0V5DmYKE

0
Ð Awarded
Michael Diagnostician
Illinois
Michael
 

Thanks Denis glad you enjoyed it.

0
Ð Awarded